TC-5901B Data Sheet Download
◆ Application
TC-5901B Pneumatic shield Box is about 50% larger in test area and height then our popular TC-595X series shield boxes providing more flexibility in handling larger devices and test fixtures. This product provides an efficient RF-isolated test environment for manufacturing mobile phones and wireless PDA's.
◆ Features
- Reliable High RF shielding up to 2.5GHz owing to simple up-down lid motion
- Pneumatic control of lid open-close and optional automatic test fixture motions
- EMI filters on all data ports and power line
- Manual or remote operation(RS-232C)
- Modular I/O design for possible customization of data and RF connection
- Fixture control air outputs for custom test fixture
- Red and Green LED for Pass/Fail indication
- Dual Pressure control and Lid Down Sensor for safety
- CE compliant : EN 292-1:1991, EN 292-2:1991/A1:1995, EN 983-1996, EN 1050:1996, EN 60204-1:1997
◆ Specification
- Shielding Effectiveness : >70dB, from DC to 2.5 GHz, including connectors
- Input are pressure : 5bar to 10bar
- Main air connector : 6mm OD hose, one-touch push-on fitting
- Fixture control air connectors : 4mm OD hose, one-touch push-on fitting
- Working space : 408(W)×218(D)×135(H) mm
- Dimension : 459(W)×300(D)×302(H) mm, lid closed. 449(H) mm, lid open
- Line voltage : 100 to 240 VAC, 50/60 Hz, 15 watt max
- Data line capacity : 100VDC, 3Amps maximum
- Weight without optional test fixture : 20 kg
◆ Ordering Information
TC-5901B, Pneumatic Shield Box
F59014A-MMM-XXXX-YY, Custom Fixture for 5901B MMM-XXXX-YYY is a unique fixture code that will be given by Tescom
5901-71, Dual open/close switch 5901-80, Spare gasket Assy, set of 2pcs.
|